MME type cubicle produced by ELKO;

– Air Insulated,
– Metal Enclosure,
– LSC2A-PI are medium voltage switchgear and controlgear with service continuity.

It is suitable for use inside the building.

There are different types of medium voltage switchgear depending on their functional characteristics.

(Example: Input/Output Switchgear with Circuit Breaker, Load Disconnector Input/Output Switchgear, etc.)

In switchgears, SF6 gas or vacuum circuit breakers are used, depending on the BUYER’s request.

Type tests have been carried out in accordance with the relevant TSE IEC standards.

ELKO Modular switchgears are manufactured in accordance with IEC 62271-200, IEC 62271-100, IEC 62271-102 standards.

MME type medium voltage switching and control devices (MV switchgears) have the relevant TSE documents.

Advantages;

Easy installation and suitability for addition on both sides thanks to the modular design.

The possibility of faulty opening/closing is eliminated by mechanical locking.

MME type cells are suitable for equipping equipment for remote monitoring and control.

Safe Switching in Sf6 Gas

Ease of Transport and Storage

Different Feeder Combinations According to Customer Request

Areas of Use;

Medium Voltage Distribution Systems (TEDAS)

Electric Power Plants (GES,HES,RES,JES)

Infrastructure and Construction Sector

Industrial Facilities

Related voltage (kV)   17.5 kV   24 kV    36 kV
Type   MME -17   MME - 24   MME-36
Rated power frequency withstand voltage (kV-rms)   38/45 kV   50/60* kV   70/80*-kV
Rated lightning impulse withstand voltage (kV-peak)   95/110* kV-peak   125/145 *kV peak   170/195 * kV peak
Rated feeder current (A)   630;1250**A   630;1250**A   630;1250**A
Rated short-circuit withstand current   16/20 kA - 1 sec   16/20 kA - 1 sec   16/20 kA - 1 sec
Rated peak withstand current (kA-peak)   40/50 kA-peak   40/50 kA-peak   40/50 kA/peak
Loss of Service Continuity   LSC2A-PI
Internal Arc Withstand   A(FL) 16 kA-1 sec
Applied standard   TS EN 62271-200
* Within the Separation Range

** Valid for Cubicle with Circuit Breakers.

 
   Description of LSC 2A-PI:
 LSC   Loss Of Service Continuity
 2A   When intervening in the accessible section of the cubicle in normal operation (Example: Cable connection section), neighboring cubicles connected to the main busbar may be energized. In other words, service continuity is not restricted.
 PI   P : There is more than one “Part”
I : At least one of the sections is separated from the other by an insulating material.

ABOUT THE PRODUCT
×